Kyoritsu KEW6205 Portable Appliance Tester
Kyoritsu KEW6205 Portable Appliance Tester Kyoritsu Portable Appliance Tester Malaysia, Selangor, Kuala Lumpur (KL), Shah Alam Supplier, Suppliers, Supply, Supplies | Enari Instruments And Controls
Download Files
6205_1E_L.pdf (1.49 MB)
CE
Protect life and property from faulty appliances
・Battery operated
・PASS / FAIL result
・Color status back light
・10 mA & 30 mA RCD test(Isolation transformer built in)
¡¡Memory function up to 999 data
・Printer output
・Complies to AS / NZS 3760
  • TRUE RMS
  • Backlight
  • USB

This instrument is suitable for performing tests as required by the following standards.
AS/NZS 3760 In-service safety inspection and testing of electrical equipment.

Test Function
Function Tests of contents
Class ¢ñ Test • Protective conductor resistance
   (Test current 200mA DC nominal)
• Insulation resistance test (250V or 500V)
• Leakage current test (100-253V/50Hz)
• Load current test (100-253V/50Hz)
Class ¢ò Test • Insulation resistance test (250V or 500V)
• Leakage current test (100-253V/50Hz)
• Load current test (100-253V/50Hz)
Extension Lead Test • Protective conductor resistance
   (Test current 200mA DC nominal)
• Insulation resistance test
   (between Line/Neutral-Earth short, Line/Neutral)
• Leakage current test (100-253V/50Hz)
• Polarity test
RCD Test • RCD test (10mA/30mA)

Mains voltage indlcation

Display range 30V-270V
Accuracy ±5V

Protective conductor resistance test

Measuring range 0.00-20.00Ω
Open circuit voltage 5V±0.4V DC
Measuring current 200mA DC(nominal value)
Accuracy ±3%rdg±5dgt

Insulation resistance test

Rated volatge 250V 500V
Measuring range 0.00-20.00MΩ
No-load voltage 250V DC +20%,-0% 500V DC +20%,-0%
Short circuit current 1.5mA DC or less
Accuracy ±2%rdg±3dgt

Load current/Leakage current test

Item Load current Leakage current
Mains voltage range 100-253V/50Hz
Measuring range 0.10-10.00A rms 0.10-20.00mA rms
Accuracy ±10%rdg±5dgt ±3%rdg±5dgt

RCD test

Rated voltage 230V -15% - +10%/50Hz
Rated current 10mA/30mA
Function × 1 × 5
Test duration 0.0ms-500.0ms 0.0ms-40.0ms
Operating time accuracy ±2ms(¨Q40ms),±8ms(>40ms)

General

Power source LR6(AA)(1.5V) × 6
Applicable Standards IEC/EN61010-1 CAT II 300V, IEC/EN61010-2-030,
IEC/EN61010-031, EN61326-2-2, AS/NZ3760
Dimensions / Weight 261(L) × 104(W) × 57(D)mm / Approx. 930g(including batteries)
Included Accessories 7277(Mains lead),
7129A(Test lead with Alligator clip),
7161A(Flat test prod),
7276(Adaptor for Extension cord),
9193(Carrying case),
8928(Fuse[10A/250V]),
9121(Shoulder strap),
Buckle, LR6(AA) x 6, Instruction manual
Optional Accessories 8263-USB(USB cable with ''KEW Report(software)''),
7275(Printer cable:Mini Din 6pin-D-sub 9pin),
7248(Test lead with Alligator clip and Flat test probe)